EMPOWERING LIFESAVERS

Sotair Training Device

$82.90
Tax included


Delivery and Shipping

All orders are despatched within 1-3 business days after order placed (please allow a couple of extra days during peak seasons and sale periods).

SHIPPING METHOD

Standard Shipping - 2-5 business days after despatch

Express Shipping - 1-2 business days after despatch 

*Based on Aust Post suggested delivery times

This device is scheduled for registration in the ARTG for clinical use late Q2’25. Listed here is a training device. Contact us for first adopter bonus 40% off.

SafeBVM’s flagship innovation, the award-winning Sotair® device, is primarily funded by grants and contracts from the National Institutes of Health (NIH), National Science Foundation (NSF), and the Military.

Sotair is a small, lightweight, easy to use flow control valve that fits between a manual resuscitator and a patient mask or airway. The valve prevents flow rates of air from exceeding 55 LPM during manual ventilation, ensuring that air delivery stays within safe limits. Flow control helps reduce peak airway pressures, excessive tidal volumes and excessive breath delivery rates, minimizing the risk of over-pressurization, over-ventilation, and hyperventilation. 

Because the Sotair is a flow limiting device, it automatically adjusts peak pressure based on the patient’s airway and lung compliance, making it suitable for any adult patient (e.g. Asthma, COPD, ARDS Pneomothorax). For example, in a patient with healthy lungs and normal airways, Sotair caps peak pressures around 20–22 cmH₂O, just below the threshold where air could enter the stomach during manual ventilation. In patients with increased airway resistance, (e.g., asthma, COPD), or restrictive lung diseases (e.g., pulmonary fibrosis, obesity hypoventilation syndrome), Sotair automatically adjusts the peak pressure limit to meet their specific needs.

 

How Sotair works:

If the bag is squeezed too quickly or forcefully causing inspiratory flow to exceed 55 LPM, Sotair’s valve closes, creating a resistance in the bag producing alarms realized by the user. Alarms are tactile and/or auditory with visual cues and prompts the user to adjust their technique encouraging the right actions, avoiding rapid, forceful squeezes that lead to unsafe ventilation.  This intuitive feedback makes training easy and reinforces best practices tailored to different patient lung conditions during real-time clinical use.

Specs:

  • Fits between a manual resuscitator and a patient mask/airway
  • Flow rates of air are limited to 55 LPM
  • Regulation of airflow helps reduce peak airway pressures, excessive tidal volumes¹ and excessive breath delivery rates,² minimizing the risk of over-pressurization, over-ventilation and hyperventilation
  • Peak Pressure limit during air delivery is automatically adjusted based on the patient's lung compliance and resistance 
  • Acts as a ‘Forcing Function,’ constraining the provider to deliver safer manual ventilation with less variability. This is most effective in ensuring system-wide change
  • Immediate real-time tactile and auditory alarms with visual cues
  • Decreases provider variability and improves consistency of ventilation
  • Reliable performance: 100% activation and flow limiting testing
  • 30 second basic training
  • NOT FOR HUMAN USE

Dimensions:

  • Weight: Sotair: 14 grams. Box with Sotair: ~110 grams
  • Size: Sotair: 5.715 cm x 3.17 cm. Box: ~7.6cm x 12.7 cm

Payment & Security

Payment methods

  • American Express
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

MyMedEquip

Sotair Training Device

$82.90

This device is scheduled for registration in the ARTG for clinical use late Q2’25. Listed here is a training device. Contact us for first adopter bonus 40% off.

SafeBVM’s flagship innovation, the award-winning Sotair® device, is primarily funded by grants and contracts from the National Institutes of Health (NIH), National Science Foundation (NSF), and the Military.

Sotair is a small, lightweight, easy to use flow control valve that fits between a manual resuscitator and a patient mask or airway. The valve prevents flow rates of air from exceeding 55 LPM during manual ventilation, ensuring that air delivery stays within safe limits. Flow control helps reduce peak airway pressures, excessive tidal volumes and excessive breath delivery rates, minimizing the risk of over-pressurization, over-ventilation, and hyperventilation. 

Because the Sotair is a flow limiting device, it automatically adjusts peak pressure based on the patient’s airway and lung compliance, making it suitable for any adult patient (e.g. Asthma, COPD, ARDS Pneomothorax). For example, in a patient with healthy lungs and normal airways, Sotair caps peak pressures around 20–22 cmH₂O, just below the threshold where air could enter the stomach during manual ventilation. In patients with increased airway resistance, (e.g., asthma, COPD), or restrictive lung diseases (e.g., pulmonary fibrosis, obesity hypoventilation syndrome), Sotair automatically adjusts the peak pressure limit to meet their specific needs.

 

How Sotair works:

If the bag is squeezed too quickly or forcefully causing inspiratory flow to exceed 55 LPM, Sotair’s valve closes, creating a resistance in the bag producing alarms realized by the user. Alarms are tactile and/or auditory with visual cues and prompts the user to adjust their technique encouraging the right actions, avoiding rapid, forceful squeezes that lead to unsafe ventilation.  This intuitive feedback makes training easy and reinforces best practices tailored to different patient lung conditions during real-time clinical use.

Specs:

Dimensions: